Itech Application Note – Inverter testing for Elevators

  • When the mains is on, it automatically recharges and keeps the batteries in top condition.
  • When mains fails it continuous to run the Elevator and bring it to a halt at the next floor.
  • The cabin bulb remains on and doors of the automatic lift opens on reaching the next floor.
  • Thus it enables safe walk-out for passengers – a real boon in these days of unpredictable power failures!

ITECH Solution’s

  • To test typical parameters of Elevator Inverter’s ITECH Electronics has a solution of power testing and measuring instrument’s like Itech AC – DC Electronic loads with regenerative, Non – regenerative type /AC – DC power supply with Regenerative and Non- Regenerative type/Power meter’s, Itech Solar array simulators Battery simulation software and so on..
  • Itech Multiple ranges of instrument with different voltage, current and power ratings.
  • Itech AC –DC Electronic loads which supports for both single phase and three phase, Master and slave technology to increase current and power level.
    • Itech IT8600 – Non Regenerative/ 1.8KVA – 14.4 KVA
    • Itech IT8200 – Regenerative /3KVA – 165KVA

Test Requirement’s

  • To test inverter at different voltage 230V/400V
  • Step function to Perform multiple power levels under CP Mode
  • To change Crest Factor from 1.414- 5.0
  • To change Power factor from 0.8 to unity
  • Waveform – Sine/Square/Triangle/Sawtooth/Trapezoid/user defined waveforms.
  • Protection – OVP/OCP/OPP/OTP
  • To Measure Harmonics

Itech AC –DC source which supports for both single phase and three phase, Master and slave technology to increase current and power level.

  • Itech IT7900P – High performance Regenerative grid simulator with source and load function which supports for single and three phase from 5KVA- 165KVA with frequency range of 16-2.4Khz
  • Itech IT7900 – Regenerative grid simulator which supports for single and three phase from 2KVA- 165KVA with frequency range of 16-2.4Khz
  • Itech IT7800 – AC-DC source which supports for single and three phase from 2KVA- 165KVA with frequency range of 16-2.4Khz
  • Itech IT7600 –AC-DC source 750VA- 3KVA with frequency range 10-5khz

Test Requirement’s

  • To test inverter at different voltage 230V/350 which supports for both single and three phase input
  • To adjust frequency levels
  • To simulate Arbitrary waveforms output
  • Built in Waveforms like sine/Square/Triangle/sawtooth/Trapezoid/User defined waveforms
  • To Test DUT from AC input fluctuation by adding surge voltage and Sag function.
  • Harmonic analysis to measure up to 50th order
  • Test the efficiency of switching power supply and catch the voltage and frequency when reaching maximum power point under sweep function

Itech DC power supply Bidirectional/unidirectional/Regenerative/Non- Regenerative type, supports for master and slave operation

Model’s – Itech IT-M3900B/C/D, Itech IT6000B/C/D ranges from 10V-2250V/1.7W – 144KW

Test Requirement’s

  • To perform battery charge at different voltage, current and power levels under CC/CV/CP/CR operational modes
  • To test the battery charge under different cut off condition like cut off voltage, current, AH, Time.
  • To test Battery pulse voltage and current under step function
  • Protection – OVP/OCP/OPP/UVP/OTP.
  • To import Battery test profile V/I/P/Ah and to test battery charge profile continuously
  • To save continuous run time of battery charge profile in .CSV format.
  • GUI to operate.

Itech DC power supply Bidirectional/unidirectional/Regenerative/Non- Regenerative type, supports for master and slave operation

Model’s

  • Itech IT8000 Regenerative DC electronic 5KW – 198KW can parallel up to 2MW
  • Itech IT8900A/E – 600W – 54KW can parallel up to 600KW
  • Itech IT8400- Regenerative DC electronic load 600W- 54KW can parallel up to 600KW
  • Test Requirement’s
  • To perform battery discharge at different voltage, current and power levels under CC/CV/CP/CR/CC+CV/CV+CR/CR+CC/CC+CV+CP+CR operational modes
  • To test the battery discharge under different cut off condition like cut off voltage, current, AH, Time.
  • To test Battery pulse voltage and current under step function
  • Protection – OVP/OCP/OPP/UVP/OTP.
  • To import Battery test profile V/I/P/Ah and to test battery discharge profile continuously
  • To save continuous run time of battery charge profile in .CSV format.
  • GUI to operate.

Itech BSS2000/BSS2000Pro/BSS2000M-Battery simulation software with Basic/Professional and Multi channel

  • In order to solve the problem of increasing cost of buying and storage of different types of batteries specifically designed for the test scenarios.
  • Battery simulator can be quickly set to different state of SoC without real charge and discharge process, greatly improve test efficiency. BSS2000Pro/BSS2000 M is developed to meet higher level testing requests. Mat file importing, BMS protocol customization and more built-in battery types are provided with the Pro version software.
  • Software combined with ITECH’s latest high-performance bidirectional DC power supply, IT6000B/IT6000C/IT-M3400/IT-M3600, covering a power range up to 1152kW, can provide users with a wide range simulation solution covering low-power battery module to high-power power battery system simulation.
  • BSS2000 Basic supports for lead acid and lithium ion batteries
  • BSS2000 Pro -Professional supports for 9 types of battery simulation like LAB,Li-on,LMO, LNMCO, LNMCO&LMO,LFP,LTO and NiMH
  • Multi channel supports for 20 Batteries simulation    Itech Authorized Partner  Itech Distributors in India  Itech suppliers in IndiaItech partners in India